Cisco Compatible CWDM-SFP25G-xxxx-10 Quick Spec:

Part Number: CWDM-SFP25G-xxxx-10 CWDM-SFP25G-xxxx-10-EXT CWDM-SFP25G-xxxx-10-IND


Form Factor: SFP28

TX Wavelength: 1270-1330nm

Reach: 10km

Cable Type: SMF

Rate Category: 25GBase

Interface Type: CWDM

DDM: Yes

Connector Type: Dual-LC

Temperature: Commercial


Cisco Compatible CWDM-SFP25G-xxxx-10 Features


Product Description

FluxLight CWDM SFP+ transceiver is a very compact 25Gb/s optical transceiver module for serial optical communication applications at 25Gb/s. The JCSE2 SFP+ converts a 25Gb/s serial electrical data stream to 25Gb/s optical output signal and a 25Gb/s optical input signal to 25Gb/s serial electrical data streams. The high speed 25Gb/s electrical interface is fully compliant with SFI specification. The high performance 12711451nm CWDM DFB transmitter and high sensitivity PIN receiver provide superior performance for Ethernet applications at up to 10km links. The SFP+ Module compliance with SFF-8431, SFF-8432 and IEEE 802.3ae 25GBASE-LR. Digital diagnostics functions are available via a 2-wire serial interface, as specified in SFF-8472. The fully SFP compliant form factor provides hot pluggability, easy optical port upgrades and low EMI emission.


Cisco Compatible CWDM-SFP25G-xxxx-10 Absolute Maximum Ratings

Parameter

Symbol

Min.

Typical

Max.

Unit

Storage Temperature

TS

-40


+100

°C

Case Operating Temperature

TA

0


70

°C

Maximum Supply Voltage

Vcc

-0.5


4

V

Relative Humidity

RH

5


95

%

Cisco Compatible CWDM-SFP25G-xxxx-10 Electrical Characteristics

(TOP = 0 to 70 °C, VCC = 3.135 to 3.465 Volts)

Parameter

Symbol

Min.

Typical

Max.

Unit

Note

Supply Voltage

Vcc

3.14


3.46

V


Supply Current

Icc



500

mA


Power Consumption

P



1.7

W


Transmitter Section:

Input differential impedance

Rin


100


Ω

1

Tx Input Single Ended DC Voltage Tolerance (Ref VeeT)

V

-0.3


4

V


Differential input voltage swing

Vin,pp

150


1200

mV

2

Transmit Disable Voltage

VD

2


Vcc

V

3

Transmit Enable Voltage

VEN

Vee


Vee+0.8

V


Receiver Section:

Single Ended Output Voltage Tolerance

V

-0.3


4

V


Rx Output Diff Voltage

Vo

350


700

mV


Rx Output Rise and Fall Time

Tr/Tf

30



ps

4

LOS Fault

VLOS fault

2


VccHOST

V

5

LOS Normal

VLOS norm

Vee


Vee+0.4

V

5


Note:

  1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC.

  2. Per SFF-8431 Rev 3.0

  3. Into 100 ohms differential termination.

  4. 20%80%

  5. LOS is an open collector output. Should be pulled up with 4.7k – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1. Maximum pull-up voltage is 5.5V.


    Cisco Compatible CWDM-SFP25G-xxxx-10 Optical Parameters

    (TOP = 0 to 70°C, VCC = 3.135 to 3.465 Volts)

    Parameter

    Symbol

    Min.

    Typical

    Max.

    Unit

    Note

    Transmitter Section:

    Center Wavelength

    λc

    λ-6.5


    λ+6.5

    nm


    spectral width

    λ



    1

    nm


    Average Optical Power

    Pavg

    -2.5


    +5.5

    dBm

    1

    Laser Off Power

    Poff



    -30

    dBm


    Extinction Ratio

    ER

    3.5



    dB


    Transmitter Dispersion Penalty

    TDP


    3@10km


    dB

    2

    Relative Intensity Noise

    Rin



    -128

    dB/Hz

    3

    Receiver Section:

    Center Wavelength

    λr

    1260


    1380

    nm


    Receiver Sensitivity(AVG)

    Sen



    -13.5

    dBm

    4

    Los Assert

    LOSA

    -30


    -

    dBm


    Los Dessert

    LOSD



    -17

    dBm


    Los Hysteresis

    LOSH

    0.5



    dB


    Overload

    Sat

    2.0



    dBm

    5

    Note:

    1. Average power figures are informative only, per IEEE802.3ae.

    2. TWDP figure requires the host board to be SFF-8431compliant. TWDP is calculated using the Matlab code provided in clause 68.6.6.2 of IEEE802.3ae.

    3. 12dB reflection.

    4. Measured at 1310nm. ER>3.5dB, PRBS231-1 and BER better than or equal to 5E-5

    5. Receiver overload specified in OMA and under the worst comprehensive stressed condition.


      Cisco Compatible CWDM-SFP25G-xxxx-10 Timing Characteristics

      Parameter

      Symbol

      Min.

      Typical

      Max.

      Unit

      TX_Disable Assert Time

      t_off



      10

      us

      TX_Disable Negate Time

      t_on



      1

      ms

      Time to Initialize Include Reset of TX_FAULT

      t_int



      300

      ms

      TX_FAULT from Fault to Assertion

      t_fault



      100

      us

      TX_Disable Time to Start Reset

      t_reset

      10



      us

      Receiver Loss of Signal Assert Time

      TA,RX_LOS



      100

      us

      Receiver Loss of Signal Deassert Time

      Td,RX_LOS



      100

      us

      Rate-Select Chage Time

      t_ratesel



      10

      us

      Serial ID Clock Time

      t_serial-clock



      100

      kHz


      Cisco Compatible CWDM-SFP25G-xxxx-10 Pin Assignment

      Diagram of Host Board Connector Block Pin Numbers and Name


      C:\Documents and Settings\Administrator\Application Data\Tencent\Users\125707287\QQ\WinTemp\RichOle\RXA]MEMX5SW@7ZX1}_`)%2L.jpg


      Pin Function Definitions

      PIN #

      Name

      Function

      Notes

      1

      VeeT

      Module transmitter ground

      1

      2

      Tx Fault

      Module transmitter fault

      2

      3

      Tx Disable

      Transmitter Disable; Turns off transmitter laser output

      3

      4

      SDL

      2 wire serial interface data input/output (SDA)


      5

      SCL

      2 wire serial interface clock input (SCL)


      6

      MOD-ABS

      Module Absent, connect to VeeR or VeeT in the module

      2

      7

      RS0

      Rate select0, optionally control SFP+ receiver. When high, input data rate >4.5Gb/ s; when low, input data rate <=4.5Gb/s


      8

      LOS

      Receiver Loss of Signal Indication

      4

      9

      RS1

      Rate select0, optionally control SFP+ transmitter. When high, input data rate >4.5Gb/s; when low, input data rate <=4.5Gb/s


      10

      VeeR

      Module receiver ground

      1

      11

      VeeR

      Module receiver ground

      1

      12

      RD-

      Receiver inverted data out put


      13

      RD+

      Receiver non-inverted data out put


      14

      VeeR

      Module receiver ground

      1

      15

      VccR

      Module receiver 3.3V supply


      16

      VccT

      Module transmitter 3.3V supply


      17

      VeeT

      Module transmitter ground

      1

      18

      TD+

      Transmitter inverted data out put


      19

      TD-

      Transmitter non-inverted data out put


      20

      VeeT

      Module transmitter ground

      1

      Note:

      1. The module ground pins shall be isolated from the module case.

      2. This pin is an open collector/drain output pin and shall be pulled up with 4.7K-10Kohms to Host_Vcc on the host board.

      3. This pin shall be pulled up with 4.7K-10Kohms to VccT in the module.

      4. This pin is an open collector/drain output pin and shall be pulled up with 4.7K-10Kohms to Host_Vcc on the host board.


SFP Module EEPROM Information and Management

    The FluxLight Series SFP modules implement the 2-wire serial communication protocol as defined in the SFP -8472.


The serial ID information of the SFP modules and Digital Diagnostic Monitor parameters can be accessed through the I2C interface at address A0h and A2h. The memory is mapped in Table 1. Detailed ID information (A0h) is listed in Table

2. And the DDM specification at address A2h. For more details of the memory map and byte definitions, please refer to the SFF-8472, The DDM parameters have been internally calibrated.


Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions)


123


Table 2 - EEPROM Serial ID Memory Contents (A0h)

Data Address

Length (Byte)

Name of Length

Description and Contents

Base ID Fields

0

1

Identifier

Type of Serial transceiver (03h=SFP)

1

1

Reserved

Extended identifier of type serial transceiver (04h)

2

1

Connector

Code of optical connector type (07=LC)

3-10

8

Transceiver

25G Base-LR

11

1

Encoding

64B/66B

12

1

BR, Nominal

Nominal baud rate, unit of 100Mbps

13-14

2

Reserved

(0000h)

15

1

Length(9um)

Link length supported for 9/125um fiber, units of 100m

16

1

Length(50um)

Link length supported for 50/125um fiber, units of 10m

17

1

Length(62.5um)

Link length supported for 62.5/125um fiber, units of 10m

18

1

Length(Copper)

Link length supported for copper, units of meters

19

1

Reserved


20-35

16

Vendor Name

SFP vendor name: AOPTICS

36

1

Reserved


37-39

3

Vendor OUI

SFP transceiver vendor OUI ID

40-55

16

Vendor PN

Part Number: “AOSP-25G-10-XX” (ASCII)

56-59

4

Vendor rev

Revision level for part number

60-62

3

Reserved


63

1

CCID

Least significant byte of sum of data in address 0-62

Extended ID Fields

64-65

2

Option

Indicates which optical SFP signals are implemented (001Ah = LOS, TX_FAULT, TX_DISABLE all supported)

66

1

BR, max

Upper bit rate margin, units of %

67

1

BR, min

Lower bit rate margin, units of %

68-83

16

Vendor SN

Serial number (ASCII)

84-91

8

Date code

Manufacturing date code

92-94

3

Reserved


95

1

CCEX

Check code for the extended ID Fields (addresses 64 to 94)

Vendor Specific ID Fields

96-127

32

Readable

Specific date, read only

128-255

128

Reserved

Reserved for SFF-8079


Cisco Compatible CWDM-SFP25G-xxxx-10 Digital Diagnostic Monitor Characteristics


Data Address

Parameter

Accuracy

Unit

96-97

Transceiver Internal Temperature

±3.0

°C

98-99

VCC3 Internal Supply Voltage

±3.0

%

100-101

Laser Bias Current

±10

%

102-103

Tx Output Power

±3.0

dBm

104-105

Rx Input Power

±3.0

dBm

Regulatory Compliance

The AOSP-25G-10-CXX(1271~1451) complies with international Electromagnetic Compatibility (EMC) and international safety requirements and standards (see details in Table following).


Electrostatic Discharge (ESD) to the Electrical Pins

MIL-STD-883E

Method 3015.7

Class 1(>1000 V)

Electrostatic Discharge (ESD) to the Duplex LC Receptacle

IEC 61000-4-2 GR-1089-CORE

Compatible with standards

Electromagnetic Interference (EMI)

FCC Part 15 Class B

EN55022 Class B (CISPR 22B)

VCCI Class B

Compatible with standards

Laser Eye Safety

FDA 21CFR 1040.10 and 1040.11 EN60950, EN (IEC) 60825-1,2

Compatible with Class 1 laser product.


Recommended Circuit


image


Recommended Host Board Power Supply Circuit


image


Recommended High-speed Interface Circuit


Mechanical Dimensions

image


Licensing

The following U.S. patents are licensed by Finisar to FluxLight, Inc.:

U.S. Patent Nos: 7,184,668, 7,079,775, 6,957,021, 7,058,310, 6,952,531, 7,162,160, 7,050,720