Arista Compatible

SFP-10G-ER-A-FL Arista SFP-10G-ER Compatible 10GBASE-ER SFP+ Transceiver, 1550nm, 40km, SMF, Duplex LC

$139.99

Free continental US shipping on orders over $99 Details

Loading...

Need a larger quantity? Request a quote

Questions? Call (888) 874-7574

Quick Specs

Rate Category
10G
Form Factor
SFP+
Interface Type
10GBASE-ER
Standard/Protocol
IEEE 802.3ae 10GBASE-ER
TX Wavelength
1550nm
RX Wavelength
1260-1600nm
Cable Type
SMF (G.652)
Reach
40km (SMF)
DDM
Supported
Connector Type
Duplex LC (UPC)
Power Consumption
< 1.5 W
Operating Temperature
0°C to +70°C (COM)

Overview

The FluxLight SFP-10G-ER-A-FL is an Arista SFP-10G-ER compatible 10GBASE-ER SFP+ transceiver for 10 Gigabit Ethernet over single-mode fiber up to 40 km. It transmits at 1550 nm, uses a duplex LC connector and supports digital diagnostics (DOM).

The SFP-10G-ER-A-FL is coded for Arista and works in any Arista switch port that takes the SFP-10G-ER, which Arista certifies on all its platforms. Platform Support has the details.

It meets IEEE 802.3ae 10GBASE-ER, so it links to any 10GBASE-ER optic at the far end, whatever its brand. It follows the SFP+ MSA and reports temperature, supply voltage, laser bias and optical power through SFF-8472 diagnostics. It uses an EML and a PIN receiver, draws under 1.5 W and is rated for a case temperature of 0 to 70 °C (commercial grade).

FluxLight guarantees it is compatible with Arista and covers it with a 10-year warranty. The TAA-compliant version is SFP-10G-ER-A-FLT.

Applications

  • 10 Gigabit Ethernet over single-mode fiber up to 40 km (10GBASE-ER/EW)
  • Metro and campus links between buildings and sites
  • Data center interconnect and switch/router uplinks over long-reach fiber

Features

  • Hot-pluggable SFP+ footprint with duplex LC receptacle
  • Supports up to 11.3 Gbps; compliant with IEEE 802.3ae 10GBASE-ER/EW
  • 1550 nm cooled EML laser transmitter and PIN photodiode receiver
  • Up to 40 km over G.652 single-mode fiber
  • Average launch power −4.7 to +4.0 dBm; receiver sensitivity better than −16 dBm
  • Real-time Digital Diagnostic Monitoring (DDM/DOM) via 2-wire serial interface per SFF-8472
  • Single +3.3V power supply, power dissipation < 1.5 W
  • Operating case temperature: 0°C to +70°C (COM)
  • SFP+ MSA (SFF-8431, SFF-8432) compliant, RoHS compliant, and Class 1 laser eye safety certified (IEC/EN 60825-1)
  • 100% compatible with and programmed for the target OEM platform
  • Backed by a FluxLight lifetime warranty

Absolute Maximum Rating

The operation in excess of any absolute maximum ratings might cause permanent damage to this module.

ParameterSymbolMinMaxUnit
Storage TemperatureTS-4085°C
Operating Case TemperatureTOP070°C
Power Supply VoltageVCC-0.33.6V
Relative Humidity (non-condensation)RH585%

Electrical and Optical Characteristics

ParameterSymbolMinTypicalMaxUnitNotes
Transmitter
Support data rate10.312511.3Gb/s
Center Wavelength15301565nm
Spectral Width (-20dB)1nm
Side Mode Suppression RatioSMSR30dB
Average Optical Output PowerPo-4.74.0dBm
Extinction RatioEr4dB
Transmitter and dispersion
penalty
TDP3.0dB1
Dispersion Tolerance1600ps/nm
Output Power with Transmitter
Disabled
Poff-30dBm
Transmitter Enable VoltageVEN00.8V
Transmitter Disable VoltageVD2.0VccV
Differential Data Input SwingVINpp120850mV
RIN12OMARIN12-128dB/Hz
Optical Return Loss ToleranceORLT21dB
Output Eye DiagramCompliant with IEEE 802.32
Receiver
Support data rate10.312511.3Gb/s
Operate Wavelength12601600nm
Receiver sensitivity (BER of
1E-12) @10.3125Gb/s
Sen1-16dBm3
Saturation (BER of 1E-12)Psat0dBm3
Receiver ReflectanceRRx-27dB
LOS AssertLOSA-30dBm
LOS De-AssertLOSD-18dBm
LOS HysteresisLOSH0.55.0dB
Differential Data Output SwingVOUTPP300850mV
LOS Low VoltageVLout0.8V
LOS High VoltageVHout2.0V
  1. For 1600 ps/nm dispersion at 10.3 Gb/s.
  2. At least 1000 waveforms acquired, with minimum 5% margin against the IEEE 802.3 mask.
  3. Tested at 10.3125Gb/s, PRBS 2³¹−1, BER of 1×10⁻¹², NRZ, including back-to-back.

Digital Diagnostic Functions

The following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise specified.

ParameterSymbolMinMaxUnit
Temperature monitor absolute errorDMI_Temp-33°C
Supply voltage monitor absolute errorDMI_VCC-0.10.1V
Channel RX power monitor absolute errorDMI_RX_Ch-33dB
Channel Bias current monitorDMI_Ibias_Ch-10%10%mA
Channel TX power monitor absolute errorDMI_TX_Ch-33dB

Mechanical Dimensions

Units: mm

SFP-10G-ER-A-FL Mechanical Dimensions

Pin Assignment and Description

SFP-10G-ER-A-FL Pin Assignment and Description
PinSignal NameDescriptionPlug Seq.Notes
1VeeTTransmitter Ground1
2TX FAULTTransmitter Fault Indication31
3TX DISABLETransmitter Disable32
4SDASDA Serial Data Signal3
5SCLSCL Serial Clock Signal3
6MOD_ABSModule Absent. Grounded within the module3
7RS0Not Connected3
8LOSLoss of Signal33
9RS1Not Connected3
10VeeRReceiver ground1
11VeeRReceiver ground1
12RD-Inv. Received Data Out34
13RD+Received Data Out34
14VeeRReceiver ground1
15VCCRReceiver Power Supply2
16VCCTTransmitter Power Supply2
17VeeTTransmitter Ground1
18TD+Transmit Data In35
19TD-Inv. Transmit Data In35
20VeeTTransmitter Ground1

Plug Seq.: pin engagement sequence during hot plugging.

  1. TX Fault is an open-collector output, which should be pulled up with a 4.7–10 kΩ resistor on the host board to a voltage between 2.0V and Vcc + 0.3V. Logic 0 indicates normal operation; logic 1 indicates a laser fault of some kind. In the low state, the output is pulled to less than 0.8V.
  2. Laser output disabled on TDIS > 2.0V or open, enabled on TDIS < 0.8V.
  3. LOS is an open-collector output. Should be pulled up with 4.7–10 kΩ on the host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
  4. RD−/+: differential receiver outputs. They are internally AC-coupled 100 Ω differential lines, which should be terminated with 100 Ω (differential) at the user SERDES.
  5. TD−/+: differential transmitter inputs. They are internally AC-coupled differential lines with 100 Ω differential termination inside the module.

ESD

This transceiver is specified as ESD threshold 1kV for high-speed data pins and 2kV for all other electrical input pins, tested per MIL-STD-883, Method 3015.4 /JESD22-A114-A (HBM). However, normal ESD precautions are still required during the handling of this module. This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and handled only in an ESD protected environment.

Laser Safety

This is a Class 1 Laser Product according to IEC 60825-1:2007. This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated (June 24, 2007).

The FluxLight SFP-10G-ER-A-FL is compatible with the Arista SFP-10G-ER, which Arista certifies on all its platforms. It works in any Arista switch port that takes the SFP-10G-ER, on any supported EOS release.

Licensing

The following is a list of Finisar Corporation patents Fluxlight has licensed. This licensure recognizes and compensates Finisar for their intellectual property. The SFP-10G-ER-A-FL, like all Fluxlight optical transceivers, is covered by this license agreement. Therefore, Fluxlight customers can rest assured that all products purchased are fully licensed, and our customers are under no potential liability that may ensue from the use of unlicensed optical transceiver products.

U.S. Patent Numbers: 7,184,668 (System and method of protecting eye safety during operation of a fiber optic transceiver), 7,079,775 (Integrated memory mapped controller circuit for fiber optics transceiver), 6,957,021 (Optical transceiver with memory mapped locations), 7,058,310 (System and method for protecting eye safety during operation of a fiber optic transceiver), 6,952,531 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,162,160 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,050,720 (Integrated memory mapped controller circuit for fiber optics transceiver)

Original Equipment Manufacturer (OEM) names may be registered trademarks of the respective OEM, and the OEM has neither authorized nor sponsored the use of its trademark or trade name. All OEM names are used for cross reference/comparative purposes only.

Warranty

This part is covered by our Limited Lifetime Warranty, a 10-year serviceable lifetime, and our 30-Day Money-Back Guarantee. Read the full warranty and return terms.

Reviews

No reviews yet. If you have used this part, yours would be the first.