QDD-400G-SR8-S-FL
400G · QSFP-DD · 850nmMMF · 100m · MPO
Need a larger quantity? Request a quote
Questions? Call (888) 874-7574
The FluxLight QDD-400G-SR8-A-FL is an Arista QDD-400G-SR8 compatible 400GBASE-SR8 QSFP-DD transceiver for 400 Gigabit Ethernet over multimode fiber up to 70 m on OM3 and 100 m on OM4. It transmits at 850 nm, uses an MPO-16 APC connector and supports digital diagnostics (DOM).
The QDD-400G-SR8-A-FL is coded for Arista and works in any Arista switch port that takes the QDD-400G-SR8, which Arista certifies on all its platforms. Platform Support has the details.
It meets IEEE 802.3cm 400GBASE-SR8, so it links to any 400GBASE-SR8 optic at the far end, whatever its brand. It follows the QSFP-DD MSA. It draws at most 12 W and is rated for a case temperature of 0 to 70 °C (commercial grade). Its reach assumes forward error correction (FEC) on the host.
FluxLight guarantees it is compatible with Arista and covers it with a 10-year warranty. The TAA-compliant version is QDD-400G-SR8-A-FLT.

| Pin | Logic | Symbol | Description |
|---|---|---|---|
| 1 | GND | Ground | |
| 2 | CML | Tx2n | Transmitter Inverted Data Input |
| 3 | CML | Tx2p | Transmitter Non-Inverted Data Input |
| 4 | GND | Ground | |
| 5 | CML | Tx4n | Transmitter Inverted Data Input |
| 6 | CML | Tx4p | Transmitter Non-Inverted Data Input |
| 7 | GND | Ground | |
| 8 | LVTTL | ModSelL | Module Select |
| 9 | LVTTL | ResetL | Module Reset |
| 10 | VccRx | Receiver +3.3V DC Power Supply | |
| 11 | LVCMOS | SCL | 2-wire serial interface clock |
| 12 | LVCMOS | SDA | 2-wire serial interface data |
| 13 | GND | Ground | |
| 14 | CML | Rx3p | Receiver Non-Inverted Data Output |
| 15 | CML | Rx3n | Receiver Inverted Data Output |
| 16 | GND | Ground | |
| 17 | CML | Rx1p | Receiver Non-Inverted Data Output |
| 18 | CML | Rx1n | Receiver Inverted Data Output |
| 19 | GND | Ground | |
| 20 | GND | Ground | |
| 21 | CML | Rx2n | Receiver Inverted Data Output |
| 22 | CML | Rx2p | Receiver Non-Inverted Data Output |
| 23 | GND | Ground | |
| 24 | CML | Rx4n | Receiver Inverted Data Output |
| 25 | CML | Rx4p | Receiver Non-Inverted Data Output |
| 26 | GND | Ground | |
| 27 | LVTTL | ModPrsL | Module Present |
| 28 | LVTTL | IntL | Interrupt |
| 29 | VccTx | Transmitter +3.3V DC Power Supply | |
| 30 | Vcc1 | +3.3V DC Power Supply | |
| 31 | LVTTL | InitMode | Initialization Mode (called LPMode in legacy QSFP applications) |
| 32 | GND | Ground | |
| 33 | CML | Tx3p | Transmitter Non-Inverted Data Input |
| 34 | CML | Tx3n | Transmitter Inverted Data Input |
| 35 | GND | Ground | |
| 36 | CML | Tx1p | Transmitter Non-Inverted Data Input |
| 37 | CML | Tx1n | Transmitter Inverted Data Input |
| 38 | GND | Ground | |
| 39 | GND | Ground | |
| 40 | CML | Tx6n | Transmitter Inverted Data Input |
| 41 | CML | Tx6p | Transmitter Non-Inverted Data Input |
| 42 | GND | Ground | |
| 43 | CML | Tx8n | Transmitter Inverted Data Input |
| 44 | CML | Tx8p | Transmitter Non-Inverted Data Input |
| 45 | GND | Ground | |
| 46 | Reserved | For future use | |
| 47 | VS1 | Module Vendor Specific 1 | |
| 48 | VccRx1 | +3.3V DC Power Supply | |
| 49 | VS2 | Module Vendor Specific 2 | |
| 50 | VS3 | Module Vendor Specific 3 | |
| 51 | GND | Ground | |
| 52 | CML | Rx7p | Receiver Non-Inverted Data Output |
| 53 | CML | Rx7n | Receiver Inverted Data Output |
| 54 | GND | Ground | |
| 55 | CML | Rx5p | Receiver Non-Inverted Data Output |
| 56 | CML | Rx5n | Receiver Inverted Data Output |
| 57 | GND | Ground | |
| 58 | GND | Ground | |
| 59 | CML | Rx6n | Receiver Inverted Data Output |
| 60 | CML | Rx6p | Receiver Non-Inverted Data Output |
| 61 | GND | Ground | |
| 62 | CML | Rx8n | Receiver Inverted Data Output |
| 63 | CML | Rx8p | Receiver Non-Inverted Data Output |
| 64 | GND | Ground | |
| 65 | NC | No Connect | |
| 66 | Reserved | For future use | |
| 67 | VccTx1 | +3.3V DC Power Supply | |
| 68 | Vcc2 | +3.3V DC Power Supply | |
| 69 | Reserved | For future use | |
| 70 | GND | Ground | |
| 71 | CML | Tx7p | Transmitter Non-Inverted Data Input |
| 72 | CML | Tx7n | Transmitter Inverted Data Input |
| 73 | GND | Ground | |
| 74 | CML | Tx5p | Transmitter Non-Inverted Data Input |
| 75 | CML | Tx5n | Transmitter Inverted Data Input |
| 76 | GND | Ground |
The optical port is an MPO-16 APC receptacle carrying 8 transmit and 8 receive multimode fibers. Proper alignment is ensured by the guide pins inside the receptacle; the cable should not be twisted, to keep channel-to-channel alignment.
Operation in excess of any individual absolute maximum rating may cause permanent damage to the module.
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| Storage Temperature | TS | -40 | 85 | °C |
| Operating Case Temperature | TOP | 0 | 70 | °C |
| Power Supply Voltage | VCC | -0.5 | 3.6 | V |
| Relative Humidity (non-condensation) | RH | 0 | 85 | % |
| Parameter | Symbol | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Operating Case Temperature | TOP | 0 | 70 | °C | ||
| Power Supply Voltage | VCC | 3.135 | 3.3 | 3.465 | V | |
| Data Rate, each Lane | 26.5625 | GBd | PAM4 | |||
| Data Rate Accuracy | -100 | 100 | ppm | |||
| Pre-FEC Bit Error Ratio | 2.4×10⁻⁴ | |||||
| Post-FEC Bit Error Ratio | 1×10⁻¹² | 1 | ||||
| Link Distance with OM3 | D | 0.5 | 70 | m | 2 | |
| Link Distance with OM4 | D | 0.5 | 100 | m | 2 |
The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified.
| Parameter | Test Point | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Power Consumption | 12 | W | ||||
| Supply Current | Icc | 3.63 | A | |||
| Transmitter (each Lane) | ||||||
| Signaling Rate, each Lane | TP1 | 26.5625 ± 100 ppm | GBd | |||
| Differential pk-pk Input Voltage Tolerance | TP1a | 900 | mVpp | 1 | ||
| Differential Termination Mismatch | TP1 | 10 | % | |||
| Differential Input Return Loss | TP1 | IEEE 802.3-2015 Equation (83E-5) | dB | |||
| Differential to Common Mode Input Return Loss | TP1 | IEEE 802.3-2015 Equation (83E-6) | dB | |||
| Module Stressed Input Test | TP1a | See IEEE 802.3bs 120E.3.4.1 | 2 | |||
| Single-ended Voltage Tolerance Range | TP1a | -0.4 | 3.3 | V | ||
| DC Common Mode Input Voltage | TP1 | -350 | 2850 | mV | 3 | |
| Receiver (each Lane) | ||||||
| Signaling Rate, each Lane | TP4 | 26.5625 ± 100 ppm | GBd | |||
| Differential Peak-to-Peak Output Voltage | TP4 | 900 | mVpp | |||
| AC Common Mode Output Voltage, RMS | TP4 | 17.5 | mV | |||
| Differential Termination Mismatch | TP4 | 10 | % | |||
| Differential Output Return Loss | TP4 | IEEE 802.3-2015 Equation (83E-2) | dB | |||
| Common to Differential Mode Conversion Return Loss | TP4 | IEEE 802.3-2015 Equation (83E-3) | dB | |||
| Transition Time, 20% to 80% | TP4 | 9.5 | ps | |||
| Near-end Eye Symmetry Mask Width (ESMW) | TP4 | 0.265 | UI | |||
| Near-end Eye Height, Differential | TP4 | 70 | mV | |||
| Far-end Eye Symmetry Mask Width (ESMW) | TP4 | 0.2 | UI | |||
| Far-end Eye Height, Differential | TP4 | 30 | mV | |||
| Far-end Pre-cursor ISI Ratio | TP4 | -4.5 | 2.5 | % | ||
| Common Mode Output Voltage (Vcm) | TP4 | -350 | 2850 | mV | 3 | |
The following optical characteristics are defined over the Recommended Operating Environment unless otherwise specified.
| Parameter | Symbol | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Transmitter | ||||||
| Center Wavelength | λC | 840 | 850 | 860 | nm | |
| Data Rate, each Lane | 26.5625 ± 100 ppm | GBd | ||||
| Modulation Format | PAM4 | |||||
| RMS Spectral Width | Δλrms | 0.6 | nm | Modulated | ||
| Average Launch Power, each Lane | PAVG | -6.5 | 4 | dBm | 1 | |
| Outer Optical Modulation Amplitude (OMAouter), each Lane | POMA | -4.5 | 3 | dBm | 2 | |
| Launch Power in OMAouter minus TDECQ, each Lane | -5.9 | dBm | ||||
| Transmitter and Dispersion Eye Closure for PAM4 (TDECQ), each Lane | TDECQ | 4.5 | dB | |||
| Extinction Ratio | ER | 3 | dB | |||
| Optical Return Loss Tolerance | TOL | 12 | dB | |||
| Average Launch Power of OFF Transmitter, each Lane | Poff | -30 | dBm | |||
| Encircled Flux | ≥ 86% at 19 μm; ≤ 30% at 4.5 μm | |||||
| Receiver | ||||||
| Center Wavelength | λC | 840 | 850 | 860 | nm | |
| Data Rate, each Lane | 26.5625 ± 100 ppm | GBd | ||||
| Modulation Format | PAM4 | |||||
| Damage Threshold, each Lane | THd | 5 | dBm | 3 | ||
| Average Receive Power, each Lane | -7.9 | 4 | dBm | 4 | ||
| Receive Power (OMAouter), each Lane | 3 | dBm | ||||
| Receiver Sensitivity (OMAouter), each Lane | SEN | -6.5 | dBm | 5 | ||
| Stressed Receiver Sensitivity (OMAouter), each Lane | SRS | -3 | dBm | 6 | ||
| Receiver Reflectance | RR | -12 | dB | |||
| LOS Assert | LOSA | -30 | dBm | |||
| LOS De-assert | LOSD | -12 | dBm | |||
| LOS Hysteresis | LOSH | 0.5 | dB | |||
| Stressed Conditions for Stressed Receiver Sensitivity | 7 | |||||
| Stressed Eye Closure for PAM4 (SECQ), Lane under Test | 4 | dB | ||||
| OMAouter of each Aggressor Lane | 3 | dBm | ||||
The following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise specified.
| Parameter | Symbol | Min | Max | Unit | Notes |
|---|---|---|---|---|---|
| Temperature monitor absolute error | DMI_Temp | -3 | 3 | °C | Over operating temperature range |
| Supply voltage monitor absolute error | DMI_VCC | -0.1 | 0.1 | V | Over full operating range |
| Channel RX power monitor absolute error | DMI_RX_Ch | -2 | 2 | dB | 1 |
| Channel bias current monitor absolute error | DMI_Ibias_Ch | -10 | 10 | % | |
| Channel TX power monitor absolute error | DMI_TX_Ch | -2 | 2 | dB | 1 |

This transceiver is specified as ESD threshold 1kV for high-speed data pins and 2kV for all other electrical input pins, tested per MIL-STD-883, Method 3015.4 /JESD22-A114-A (HBM). However, normal ESD precautions are still required during the handling of this module. This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and handled only in an ESD protected environment.
This is a Class 1 Laser Product according to EN 60825-1:2014. This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated (June 24, 2007).
Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
FluxLight is fully committed to environment protection and sustainable development and has set in place a comprehensive program for removing polluting and hazardous substances from all of its products. The relevant evidence of RoHS compliance is held as part of our controlled documentation for each of our compliant products. RoHS compliance parts are available to order, please refer to the ordering information section for further details.
The FluxLight QDD-400G-SR8-A-FL is compatible with the Arista QDD-400G-SR8, which Arista certifies on all its platforms. It works in any Arista switch port that takes the QDD-400G-SR8, running EOS 4.24.0 or later.
The following is a list of Finisar Corporation patents Fluxlight has licensed. This licensure recognizes and compensates Finisar for their intellectual property. The QDD-400G-SR8-A-FL, like all Fluxlight optical transceivers, is covered by this license agreement. Therefore, Fluxlight customers can rest assured that all products purchased are fully licensed, and our customers are under no potential liability that may ensue from the use of unlicensed optical transceiver products.
U.S. Patent Numbers: 7,184,668 (System and method of protecting eye safety during operation of a fiber optic transceiver), 7,079,775 (Integrated memory mapped controller circuit for fiber optics transceiver), 6,957,021 (Optical transceiver with memory mapped locations), 7,058,310 (System and method for protecting eye safety during operation of a fiber optic transceiver), 6,952,531 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,162,160 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,050,720 (Integrated memory mapped controller circuit for fiber optics transceiver)
Original Equipment Manufacturer (OEM) names may be registered trademarks of the respective OEM, and the OEM has neither authorized nor sponsored the use of its trademark or trade name. All OEM names are used for cross reference/comparative purposes only.
This part is covered by our Limited Lifetime Warranty, a 10-year serviceable lifetime, and our 30-Day Money-Back Guarantee. Read the full warranty and return terms.
No reviews yet. If you have used this part, yours would be the first.


12 in stock
Order by 3 PM CT for same-day shipping

400G · QSFP-DD · 850nmMMF · 100m · MPO

400G · QSFP-DD · 850nmMMF · 100m · MPO

400G · QSFP-DD · 850nmMMF · 100m · MPO

400G · QSFP-DD · 850nmMMF · 100m · MPO