Fine optics at a fine price
Price is great for these units, can't be beat really.
Need a larger quantity? Request a quote
Questions? Call (888) 874-7574
The FluxLight SFP-10G-LR-FL is a Cisco SFP-10G-LR compatible 10GBASE-LR SFP+ transceiver for 10 Gigabit Ethernet over single-mode fiber up to 10 km. It transmits at 1310 nm, uses a duplex LC connector and supports digital diagnostics (DOM).
The SFP-10G-LR-FL is coded for Cisco and works in the Cisco ports that take the SFP-10G-LR, including Catalyst 9200, 9300, 9400 and 9500 switches, Nexus 3000 and 9000 switches, and Cisco 8000 routers. Platform Support lists every model, taken from Cisco's transceiver compatibility matrix.
It meets IEEE 802.3ae 10GBASE-LR (IEEE 802.3 Clause 52), so it links to any 10GBASE-LR optic at the far end, whatever its brand. It follows the SFP+ MSA (SFF-8431) and reports temperature, voltage, laser bias and optical power through SFF-8472 diagnostics. It uses a 1310 nm DFB laser and a PIN receiver, draws under 1 W and is rated for a case temperature of 0 to 70 °C (commercial grade).
FluxLight guarantees it is compatible with Cisco and covers it with a 10-year warranty. The TAA-compliant version is SFP-10G-LR-FLT.
The operation in excess of any absolute maximum ratings might cause permanent damage to this module.
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| Storage Temperature | TS | -40 | 85 | °C |
| Operating Case Temperature | TOP | 0 | 70 | °C |
| Power Supply Voltage | VCC | -0.3 | 3.6 | V |
| Relative Humidity (non-condensation) | RH | 5 | 85 | % |
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Operating Case Temperature | TOP | 0 | 70 | °C | |
| Power Supply Voltage | VCC | 3.135 | 3.3 | 3.465 | V |
| Power Consumption | 1 | W | |||
| Data Rate | DR | 10.3125 | Gbps | ||
| Link Distance with SMF | D | 10 | km |
| Parameter | Symbol | Min | Typical | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Transmitter | ||||||
| Support data rate | 1.25 | 11.3 | Gb/s | |||
| Center Wavelength | 1260 | 1310 | 1355 | nm | ||
| Spectral Width (-20dB) | 1 | nm | ||||
| Side Mode Suppression Ratio | SMSR | 30 | dB | |||
| Average Optical Output Power | Po | -8.2 | 0.5 | dBm | ||
| Optical Modulation Amplitude | POMA | -5.2 | dBm | |||
| Extinction Ratio | Er | 3.5 | dB | |||
| Transmitter and dispersion penalty | TDP | 3.2 | dB | |||
| Output Power with Transmitter Disabled | Poff | -30 | dBm | |||
| Transmitter Enable Voltage | VEN | -0.3 | 0.8 | V | ||
| Transmitter Disable Voltage | VD | 2.0 | Vcc+0.3 | V | ||
| Differential Data Input Swing | VINpp | 100 | 1000 | mV | ||
| Rise/fall time (20%-80%) | Tr/Tf | 50 | ps | |||
| RIN12OMA | RIN12 | -128 | dB/Hz | |||
| Optical return loss tolerance | 12 | dB | ||||
| Output Eye Diagram | Compliant with IEEE 802.3 | 1 | ||||
| Receiver | ||||||
| Support data rate | 1.25 | 10.3125 | 11.3 | Gb/s | ||
| Operate Wavelength | 1260 | 1580 | nm | |||
| Receiver sensitivity (BER of 1E-12) @10.3125Gb/s | Sen1 | -14.4 | dBm | 2 | ||
| Saturation (BER of 1E-12) | Psat | 0.5 | dBm | 2 | ||
| LOS Assert | LOSA | -30 | dBm | |||
| LOS De-Assert | LOSD | -16 | dBm | |||
| LOS Hysteresis | LOSH | 0.5 | 5.0 | dB | ||
| Differential Data Output Swing | VOUTPP | 300 | 850 | mV | ||
| LOS Low Voltage | VLout | 0.4 | V | |||
| LOS High Voltage | VHout | 2.0 | V | |||

The following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise specified.
| Parameter | Symbol | Min | Max | Unit |
|---|---|---|---|---|
| Temperature monitor absolute error | DMI_Temp | -5 | 5 | °C |
| Supply voltage monitor absolute error | DMI_VCC | -0.1 | 0.1 | V |
| RX power monitor absolute error | DMI_RX | -3 | 3 | dB |
| Bias current monitor absolute error | DMI_Ibias | -10% | 10% | mA |
| TX power monitor absolute error | DMI_TX | -3 | 3 | dB |
Units: mm


| Pin | Signal Name | Description | Plug Seq. |
|---|---|---|---|
| 1 | VeeT | Transmitter Ground | 1 |
| 2 | TX FAULT | Transmitter Fault Indication | 3 |
| 3 | TX DISABLE | Transmitter Disable | 3 |
| 4 | SDA | SDA Serial Data Signal | 3 |
| 5 | SCL | SCL Serial Clock Signal | 3 |
| 6 | MOD_ABS | Module Absent. Grounded within the module | 3 |
| 7 | RS0 | Not Connected | 3 |
| 8 | LOS | Loss of Signal | 3 |
| 9 | RS1 | Not Connected | 3 |
| 10 | VeeR | Receiver ground | 1 |
| 11 | VeeR | Receiver ground | 1 |
| 12 | RD- | Inv. Received Data Out | 3 |
| 13 | RD+ | Received Data Out | 3 |
| 14 | VeeR | Receiver ground | 1 |
| 15 | VCCR | Receiver Power Supply | 2 |
| 16 | VCCT | Transmitter Power Supply | 2 |
| 17 | VeeT | Transmitter Ground | 1 |
| 18 | TD+ | Transmit Data In | 3 |
| 19 | TD- | Inv. Transmit Data In | 3 |
| 20 | VeeT | Transmitter Ground | 1 |
This transceiver is specified as ESD threshold 1kV for high-speed data pins and 2kV for all other electrical input pins, tested per MIL-STD-883, Method 3015.4 /JESD22-A114-A (HBM). However, normal ESD precautions are still required during the handling of this module. This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and handled only in an ESD protected environment.
This is a Class 1 Laser Product according to IEC 60825-1:2007. This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated (June 24, 2007).
The following is a list of Finisar Corporation patents Fluxlight has licensed. This licensure recognizes and compensates Finisar for their intellectual property. The SFP-10G-LR-FL, like all Fluxlight optical transceivers, is covered by this license agreement. Therefore, Fluxlight customers can rest assured that all products purchased are fully licensed, and our customers are under no potential liability that may ensue from the use of unlicensed optical transceiver products.
U.S. Patent Numbers: 7,184,668 (System and method of protecting eye safety during operation of a fiber optic transceiver), 7,079,775 (Integrated memory mapped controller circuit for fiber optics transceiver), 6,957,021 (Optical transceiver with memory mapped locations), 7,058,310 (System and method for protecting eye safety during operation of a fiber optic transceiver), 6,952,531 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,162,160 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,050,720 (Integrated memory mapped controller circuit for fiber optics transceiver)
Original Equipment Manufacturer (OEM) names may be registered trademarks of the respective OEM, and the OEM has neither authorized nor sponsored the use of its trademark or trade name. All OEM names are used for cross reference/comparative purposes only.
This part is covered by our Limited Lifetime Warranty, a 10-year serviceable lifetime, and our 30-Day Money-Back Guarantee. Read the full warranty and return terms.
Price is great for these units, can't be beat really.
Great price and works like a charm! Also got shipped insanely fast.
Always a pleasure to work with the sales staff. Very responsive and accommodating on costs.
These SFPs have worked flawlessly with our CISCO gear for many years. Highly recommend!
same performance as the OEM component for a fraction of the price. Have been using this exact model since 2017 with no issues
Awesome
Everything we purchase form FluxLight works with no issues. Great customer service and speedy delivery!
Just as good as OEM. Works great.
We've installed several of these and have yet to have a problem with compatibility.
10 years of great product/pricing/and great customer service, I cant ask for anything more from Fluxlight!!! Joseph From St. Louis MO. USA
Showing 10 of 36 reviews


5,714 in stock
Order by 3 PM CT for same-day shipping

10G · SFP+ · 1310nmSMF · 10km · Duplex LC

10G · SFP+ · 1310nmSMF · 10km · Duplex LC

10G · SFP+ · 1310nmSMF · 10km · Duplex LC

10G · SFP+ · 1310nmSMF · 10km · Duplex LC